STFC SERIES TENSION LOAD CELLS

ATEX VERSION
  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Tension load cells CE-M approved for suspended weighing of hoppers, tanks, etc.


CAPACITIES (kg): 2000, 5000, 10000.


OIML R60. C3 precision class.


Nickel-plated steel. IP67 protection.


MAIN FEATURES

  • C3 PRECISION CLASS
  • NICKEL-PLATED STEEL CONSTRUCTION
  • IP67 PROTECTION LEVEL
  • MAX. CAPACITIES FROM 2000 TO 10000 kg
  • SHIELDED CONNECTION CABLE
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC = 3000
  • Combined error: 0,02% of Full Scale Output (F.S.)
  • Full Scale Output: 2mV/V +/- 0,1%
  • Temperature effect on zero: 0,0013% /°C
  • Temperature effect on full scale output: 0,0014% /°C
  • Compensated Temperature Range: –10°C/+40°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 4 hours: 0,03% F.S.
  • Maximum tolerated excitation voltage: 10 VDC
  • Input Resistance: 1100 Ohm
  • Output Resistance: 1000 Ohm
  • Zero balance: +/-1% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 300% F.S.
  • 4-wire shielded cable, 5m long, 5mm diameter