“PLZ”: ALUMINIUM LOAD CELLS KIT FOR ASSEMBLING FLOOR SCALES

RESTING FEET

  • Adjustable in height
  • Structure nikel-plated steel
  • Anti-slip base
  • Ipersanitizable

JUNCTION BOX

  • Built-in junction and equalisation board
  • IP67 protection from dust and water
  • 5 PG9 Fairleads

Ideal for creating platforms with 4 load cells of various sizes and capacities. The kit is made up of 4 IP67 aluminium load cells, OIML approved, together with adjustable nickel-plated steel resting feet and an equalisation box.

LOAD CELL TECHNICAL FEATURES

  • Material: aluminium
  • Precision class: OIML R60 C3
  • Full scale output (FS): 2.0mV/V ± 0.1%
  • Maximum capacities: 300kg - 500kg - 1000kg
  • Maximum number of verification intervals (nLC): 3000
  • Minimum verification interval Vmin (Y=Emax/Vmin): 10000
  • Combined error (%FS): ≤± 0.03
  • Repeatibility: 0,02% Emax
  • Creep error after 30 minutes: 0,03% di Emax
  • Zero balance: < ± 1% di Emax
  • Power supply (recomended): 10 Vdc
  • Power supply (ultimate): 15Vdc
  • Input resistance: 1000 ± 20Ω
  • Output resistance: 1000 ± 20Ω
  • Insulation resistence: ≥5000MΩ
  • Compensated Temperature Range : -10 ~ +50 °C
  • Operating Temperature Range: -20 ~ +60 °C
  • Safe overload: 120 % di Emax
  • 2m shielded connection wire

“PLT” SERIES’ 350 Ohm NIKEL-PLATED LOAD CELL KITS FOR ASSEMBLING FLOOR SCALES

RESTING FEET

  • Adjustable in height
  • Nikel-plated steel structure
  • Anti-slip base
  • Ipersanitizable
  • Fitted with locking bush

JUNCTION BOX

  • Built-in junction and equalisation board
  • IP67 protection from dust and water
  • 1 PG9 Fairlead and 4 PG7 Fairleads
Ideal for creating platforms with 4 load cells of various sizes and capacities. The kit is made up of 4 350 Ohm IP67 nikel-plated load cells, OIML and NTEP approved, together with adjustable resting feet and an equalisation box.

LOAD CELL TECHNICAL FEATURES

  • Minimum load cell verification interval Vmin = EMax / 10.000
  • Maximum number of verification intervals nLC = 3000
  • Combined error 0,017% of Full Scale Output (F.S.)
  • Nonlinearity ± 0.02% FS
  • Hysteresis ± 0.02% FS
  • Repeatability ± 0.01% FS
  • Full Scale Output 2mV/V ± 0.5%
  • Zero balance ± 1% FS
  • Compensated Temperature Range -10°C/+50°C.
  • Operating Temperature Range -20°C/+60°C.
  • Creep error after 30 minutes <0,02% F.S.
  • Maximum tolerated excitation voltage 15 Vdc
  • Input Resistance 380 ± 20 Ohm
  • Output Resistance 350 ± 5 Ohm
  • Insulation Resistance >5000 MOhm
  • Safe Overload 150% F.S.
  • Ultimate Overload 300% F.S.
  • 6-wire shielded cable, 3.5m long, 5 mm diameter

“PLK-1” SERIES’ 350 Ohm LOAD CELL KITS FOR ASSEMBLING FLOOR SCALES

RESTING FEET

  • Adjustable in height
  • Structure in STAINLESS steel
  • Anti-slip base
  • Ipersanitizable
  • Fitted with locking bush

JUNCTION BOX

  • Built-in junction and equalisation board
  • IP67 protection from dust and water
  • 5 PG9 Fairleads

Ideal for creating platforms with 4 load cells of various sizes and capacities. The kit is made up of 4 350 Ohm IP68 stainless steel load cells, OIML approved, together with adjustable stainless steel resting feet and an equalisation box.

LOAD CELL TECHNICAL FEATURES

  • C3 precision class
  • Stainless steel construction with laser weldings
  • IP68 protection
  • Max. Capacities from 300 to 2000 kg (for each load cell)
  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC = 3000
  • Combined error: 0,017% of Full Scale Output (F.S.)
  • Full Scale Output: 2mV/V +/- 0.1%
  • Temperature effect on zero: 0,0014% /°C
  • Temperature effect on full scale output: 0,0014% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 30 minutes: 0,024% F.S.
  • Maximum tolerated excitation voltage: 15 Vdc
  • Input Resistance: 385 ± 20 Ohm
  • Output Resistance: 350 ± 5 Ohm
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 200% F.S.