SPBC SERIES SINGLE POINT LOAD CELLS

Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 700x700 mm.


CAPACITIES (kg): 100, 200, 300, 500, 630.


OIML R60. C3 precision class.


Aluminium alloy. IP65 protection.


MAIN FEATURES

  • C3 PRECISION CLASS
  • OFF CENTER LOAD COMPENSATED
  • MADE IN ALUMINIUM ALLOY
  • IP65 PROTECTION
  • MAX. CAPACITIES FROM 100 TO 630kg
  • FOR PLATFORMS WITH DIMENSIONS UP TO 700 X 700 mm
  • SHIELDED CONNECTION CABLE
  • OIML CERTIFICATE AVAILABLE UPON REQUEST
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC = 3000
  • Full Scale Output: 2mV/V +/- 10%
  • Combined error: 0,017% of Full Scale Output (F.S.)
  • Temperature effect on zero: 0,0028% /°C
  • Temperature effect on full scale output: 0,0014% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 30 minutes: 0,025% F.S.
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 410 ± 10 Ohm
  • Output Resistance: 350 ± 5 Ohm
  • Zero Balance: +/-10% F.S.
  • Insulation Resistance: >1000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 200% F.S.
  • Nominal displacement: < 1mm
  • SPBC 6-wire shielded cable, 3m long, 5mm diameter

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.